Three Zone Outdoor Unit 27,000 BTU
Overview
Three Zone Inverter Air Conditioners provide cooling and heating and compact, quiet, stylish wall-mounted design which perfectly blends into any environment. These units have optimized air duct design for a range of noise reduction measures resulting in ultra-low noise performance. In addition, with new SEER 23 standard compatibility our units are among the MOST ENERGY EFFICIENT on the market.
Model: AM3M27O
27000BTU Multi Zone Unit
SEER 21.5
HSRF 11.5
Product Specifications
Outdoor | AM3M27O | ||
---|---|---|---|
Power supply | Ph-V-Hz | 208-230V~ 60Hz , 1Ph | |
Cooling | Capacity | Btu/h | 28000 |
EER | Btu/w | 12.5 | |
SEER | 23 | ||
Heating at 47F | Capacity | Btu/h | 28000 |
COP | Btu/w | 3.9 | |
HSPF4 | 10.3 | ||
Heating at 17F | Rated capacity | Btu/h | 17200 |
Heating at 5 F(-15°C) | Maximum capactiy
| Btu/h | 21900 |
MINIMUM CIRCUIT AMPACITY | A | 25.0 | |
MAX.FUSE | A | 35.0 | |
Compressor | Model | ATF235D22UMT | |
Type | ROTARY | ||
Brand | GMCC | ||
Capacity | Btu/h | 24345 | |
Input | W | 1970 | |
Rated current(RLA) | A | 20.00 | |
Locked rotor Amp(LRA) | A | – | |
Thermal protector | – | ||
Thermal protector position | – | ||
Refrigerant oil/oil charge | ml | POE(VG74)/670 | |
Outdoor fan motor | Model | ZKFN-120-8-2 | |
Brand | Welling | ||
Input | W | 150 | |
RLA | A | 0.9 | |
LRA | A | – | |
Winding Resistance | Ω | – | |
Capacitor | uF | – | |
Speed | r/min | 150/200/250/300/ 400/500/600/ 750/900/1000 | |
Outdoor air flow | m3/h | 3619 | |
Outdoor air flow | CFM | 2130 | |
Outdoor noise level | min/max | dB(A) | 30-58 |
Outdoor unit | Dimension(W*D*H) | mm | 946x410x810 |
Dimension(W*D*H) | inch | 37.24×16.14×31.89 | |
Packing (W*D*H) | mm | 1090x500x875 | |
Packing (W*D*H) | inch | 42.91×19.69×34.45 | |
Net/Gross weight | Kg | 68/73 | |
Net/Gross weight | lbs. | 149.91/160.94 | |
Refrigerant type | oz | R410A/98.8 | |
Refrigerant precharge (Total pipe length) | ft | 25 | |
Additional charge for each ft | oz | 0.161 | |
Design pressure | PSIG | 550/340 | |
Refrigerant piping | Liquid side/ Gas side | mm(inch) | 3 X Φ6.35/ Φ9.52 (1/4″/3/8″) |
Max. length for all rooms | m | 60 | |
Max. length for all rooms | ft | 197 | |
Max. length for one indoor unit | m | 30 | |
Max. length for one indoor unit | ft | 98 | |
Max. height difference between indoor and outdoor unit | m | 15 | |
ft | 49 | ||
Max. height difference between indoor units | m | 10 | |
Max. height difference between indoor units | ft | 33 | |
Connection wiring | NO | ||
Ambient temperature | cooling | ℃ | -25~50 |
cooling | ℉ | -13~122 | |
heating | ℃ | -25~30 | |
heating | ℉ | -13~86 |